Correct logic to exclude i386 inline assenbly when -O0

The i386 MPI inline assembly code was being incorrectly included when
all compiler optimisation was disabled.
This commit is contained in:
Simon Butcher 2018-07-23 09:46:50 +01:00
parent 948f264302
commit e08754762d

View File

@ -56,7 +56,7 @@
* This is done as the number of registers used in the assembly code doesn't
* work with the -O0 option.
*/
#if defined(__i386__) && !defined(__OPTIMIZE__)
#if defined(__i386__) && defined(__OPTIMIZE__)
#define MULADDC_INIT \
asm( \